Introducing the 500-MS Ion Trap Varian 500-MS LC Ion Trap

The Varian 500-MS LC Ion Trap is the instrument of choice for high-throughput LC/MS analysis where sensitivity, reliability and productivity are essential.

The Varian 500-MS provides a robust platform for demanding LC/MS/MS applications. The system sensitivity, mass resolution, and mass stability reflect the ion trap technology’s inherent advantages, while the new enhanced charge capacity extends the number of ions that can be stored in the ion trap resulting in greater sensitivity and reduced background while delivering reliable qualitative and quantitative results.

By delivering excellent sensitivity over the entire mass range in full scan mode, and exceptional MS/MS and MSn capabilities, theVarian 500-MS quickly provides superior information for even the most complex sample matrices."

Sensitivity enhancements include SelecTemp™, the unique temperature programmable API (Atmospheric Pressure Ionization), enabling optimal analysis of thermally labile compounds. All of these technical capabilities lead to the remarkable performance and productivity delivered by the Varian 500-MS LC ion trap.

Doubly Charged Normal 5,000

Singly Charged Fast 15,000

State-of-the-art API capability

The Varian 500-MS delivers increased sensitivity and selectivity through optimized analysis of all analytes, including highly thermally labile compounds, using Varian, Inc.’s patent pending temperature programmable SelecTemp™ API interface. Maintaining sample integrity is no longer a concern. SelecTemp’s programmable temperature control delivers optimum drying gas temperatures at every time point throughout a complex analysis. Additional SelecTemp API benefits include reduced interface contamination, improved throughput, simplified setup and easily recordable parameters for GLP purposes.

Premium scanning and the power of MSn

Achieve unit mass resolution with uncompromised qualitative and quantitative results for narrow or coeluting chromatographic peaks at scan speeds of up to 15,000 Da/sec with the patented ‘unidirectional triple resonance’ scan method that preferentially ejects all the trapped ions toward the detector. The fast scan speed is complemented by rapid ion polarity switching of 200 milliseconds to accommodate the optimum detection of ion polarity for every analyte in the sample. Enhanced qualitative information is delivered by the 500-MS with MSn operation to n=10, expanding the spectral information content for structure elucidation.

New 212-LC dedicated chromatography pump for LC/MS. Enhances throughput and sensitivity for environmental and pharmaceutical analyses. Find out more here....

The Complete Solution
Sample Prep
HPLC columns
LC Instrumentation
Data Systems
Support & Training

Resources
MS Bibliography
LC/MS Reference Guide (.pdf)
Application Notes
Analytical Training Courses
Events
Information Request Form
500-MS Brochure
Benefits of API Temperature Programmable Drying Gas Analysis in LC/MS and LC/MS/MS Technical Poster (.pdf)

Application Notes
#23:   Detection of Alprazolam and Temazepam in a Bovine Plasma Matrix
#22: Preliminary Method Performance of EPA Method 535
#21: Detection of Morphine and Morphine-Glucuronide in Saliva and Urine
with a Single, Rapid, LC Ion Trap Method Without Derivatization
#20: Analysis of Polymer Antioxidant Additives

Advantage Notes
How the unique features of your 500-MS work to give you that extra advantage
Atmospheric Pressure Ionization Interface
Enhanced Charge Capacity ECC™
SelecTemp™
Fast ion polarity switching with the 500-MS system
High mass sensitivity on the Varian 500-MS
Triple resonance mass scanning on a Varian 500-MS
Reduced noise advantages with the Varian 500-MS ion optics
Large matrix effects in ion traps
Advantages of fast scan rates
 