Varian, Inc. is a global technology company that builds leading-edge tools and solutions for diverse, high-growth applications in life science and industry.
Fluorescence
Cary Eclipse
Cary Eclipse Microplate reader

Rapid Mix accessory

The RX.2000 Rapid Mix accessory from Applied Photophysics is a stop flow accessory that allows you to start measuring reagents as soon as they have been mixed.  This is an obvious advantage for reactions which are short-lived.

The syringes are mounted on a rigid drive platform ensuring that the flow is stopped precisely and instantaneously. This platform and the syringe mounting blocks are extremely resistant to chemical attack.

Reagents travel in this inert sample circuit through an umbilical cord to the flow cell where they are mixed by a high efficiency T-format mixer.

Varian offers both the RX.2000accessory from Applied Photophysics and the SFA-20 from Hi-Tech Scientific.

Key Features of the RX.2000

  • Short Dead Time The dead time of the RX.2000is only 6ms, as determined by the protocol of Tonomura et al (Anal. Biochem 84, p370-383, 1978). This enables first order reaction rates over 200s-1 to be measured.
  • Total Thermostatting. Uniquely, the entire flow circuit of the RX.2000is thermostated (including drive syringes). In addition to providing reliable temperature equilibration, this also has the added benefit of aiding in the rigorous exclusion of oxygen from the entire sample when undertaking anaerobic work.
  • Chemical resistant materials. Carefully selected materials are used throughout to protect the instrument from aggressive chemical spillage.
  • Wide temperature range. High performance syringes with canted seals are used exclusively, providing reliable operation over a wide temperature range.
  • Large ratio mixing capability. The drive syringes can be readily substituted to allow mixing ratios from 1:1 to 1:25.
  • Universal compatibility. The RX.2000cell can be fitted in seconds without tools to ANY spectrometer that can accommodate a standard 1cm rectangular cell.
  • Exceptional Sample Economy. The prime volume of the RX.2000is only 260 µl per reagent (with the standard umbilical length of 60cm) and the subsequent volume per shot is only 100 µl. Other lengths of umbilical can be supplied on request.
  • No Birefringence. The advanced micro-cell is configured optically for both absorption, fluorescence and circular dichroism. Crucially for circular dichroism (CD) and anisotropy experiments the cell is triple-annealed during manufacture to eliminate birefringence artefacts.
  • Adjustable Drive Volume. The volume required per determination can be altered by adjusting the position of the stopping block/trigger mechanism. This flexibility is of particular importance when performing large ratio asymmetric mixing experiments, and when eliminating air bubbles from the flow circuit.
  • Armoured Umbilical. The 60cm umbilical is armoured to prevent damage.The observation cell can therefore be positioned through tight turns without constricting the flow of the thermostatt fluid.
  • Triggering. The RX.2000is provided with the following popular triggering configurations, TTL, open collector and switch contact. The trigger output is accessed by a standard 5 pin DIN socket.
  • Digital Temperature Display.This integral feature, fitted as standard, indicates the sample temperature in the cell to within 0.10C. It also features programmable high and low temperature alarms.

Specifications

8 ms
2 mm and 10 mm for absorbance/circular dichroism
Window Sizes: 30 mm and 6 mmfor fluorescence detection
Spectrosil
Triple-annealed observation cell eliminating birefringence
15 mm from base of cuvette (other beam heights supplied on request)
 
260 µL with standard 60cm umbilical
Syringe Volume
Up to 25:1 by using different size syringes
0-60 °C displayed to within 0.1 °C with high and low adjustable alarms
Anti-bounce, TTL, open-collector and switch-contact
Biocompatible and chemically inert
Constructed from chemically resistant materials throughout
An anaerobic accessory is available to facilitate the rigorous exclusion of oxygen
Manually or pneumatically driven (optional accessory)

Ordering information

Description Part number

Applied Photophysics Rapid mix RX2000
NOTE: Pneumatic drive not included

7910041000

Pneumatic Drive For RX2000 7910041100

The Complete Solution
Features
Specifications
Ordering information
Software
Accessories
Application notes
Validation
21 CFR Part 11 compliance
FREE ADL programs

Fluorescence Resources

E-mail support
24/7 Service Request Form
Literature
Software patches and updates
Software version information
Recommended PC configurations
Brochure (.pdf, 1.2MB) |
DE (.pdf, 427K)

 
Contact Us | Site Map | Terms of Use | Privacy Policy | Company | © 2009 Varian, Inc.